Speed Test: 59.17 MB/s
Error: Current Pending Sector
SMART Health Assessment: PASSED
| ID# | ATTRIBUTE NAME | FLAG | VALUE | WORST | THRESH | TYPE | UPDATED | WHEN FAILED | RAW_VALUE |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Raw Read Error Rate | 0x002f | 200 | 200 | 051 | Pre-fail | Always | - | 0 |
| 3 | Spin Up Time | 0x0027 | 184 | 182 | 021 | Pre-fail | Always | - | 1775 |
| 4 | Start Stop Count | 0x0032 | 099 | 099 | 000 | Old age | Always | - | 1812 |
| 5 | Reallocated Sector Ct | 0x0033 | 200 | 200 | 140 | Pre-fail | Always | - | 0 |
| 7 | Seek Error Rate | 0x002e | 100 | 253 | 000 | Old age | Always | - | 0 |
| 9 | Power On Hours | 0x0032 | 097 | 097 | 000 | Old age | Always | - | 2601 |
| 10 | Spin Retry Count | 0x0032 | 100 | 100 | 000 | Old age | Always | - | 0 |
| 11 | Calibration Retry Count | 0x0032 | 100 | 100 | 000 | Old age | Always | - | 0 |
| 12 | Power Cycle Count | 0x0032 | 099 | 099 | 000 | Old age | Always | - | 1765 |
| 191 | G-Sense Error Rate | 0x0032 | 001 | 001 | 000 | Old age | Always | - | 4064 |
| 192 | Power-Off Retract Count | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 48 |
| 193 | Load Cycle Count | 0x0032 | 197 | 197 | 000 | Old age | Always | - | 11101 |
| 194 | Temperature Celsius | 0x0022 | 116 | 091 | 000 | Old age | Always | - | 31 |
| 196 | Reallocated Event Count | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 0 |
| 197 | Current Pending Sector | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 1 |
| 198 | Offline Uncorrectable | 0x0030 | 100 | 253 | 000 | Old age | Offline | - | 0 |
| 199 | UDMA CRC Error Count | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 0 |
| 200 | Multi Zone Error Rate | 0x0008 | 100 | 253 | 000 | Old age | Offline | - | 0 |
| 240 | Head Flying Hours | 0x0032 | 097 | 097 | 000 | Old age | Always | - | 2578 |
| 241 | Total LBAs Written | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 6694272220 |
| 242 | Total LBAs Read | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 15210548045 |
| 254 | Free Fall Sensor | 0x0032 | 200 | 200 | 000 | Old age | Always | - | 0 |
Drive will be re-tested for quality control before being shipped.